• Schneider ATV9A0C45Q4 Variable speed drive Altivar Process Modular, ATV900, single drive, 400V, 450 kW

Schneider ATV9A0C45Q4 Variable speed drive Altivar Process Modular, ATV900, single drive, 400V, 450 kW

Main
range of product
Altivar Process ATV900
product or component type
Variable speed drive
product specific application
Process and utilities
device short name
ATV9A0
variant
Modular version
product destination
Asynchronous motors
Synchronous motors
mounting mode
Cabinet mount
kit composition
Mechanical mounting kits
Power connection
Set of fuses
1 control unit
3 power module 160 kW
2 front cover
EMC filter
Integrated conforming to EN/IEC 61800-3 category C3 with <= 300 m motor cable maxi
IP degree of protection
IP00 conforming to IEC 61800-5-1 for IP21 or IP54 cabinet integration
IP00 conforming to IEC 60529 for IP21 or IP54 cabinet integration
type of cooling
Forced convection
supply frequency
50...60 Hz +/- 5 %
network number of phases
3 phases
[Us] rated supply voltage
400 V - 15...10 %
motor power kW
450 kW at 400 V (normal duty)
355 kW at 400 V (heavy duty)
line current
764 A at 400 V (normal duty)
611 A at 400 V (heavy duty)
prospective line Isc
50 kA
apparent power
529 kVA at 400 V (normal duty)
423 kVA at 400 V (heavy duty)
continuous output current
830 A at 2.5 kHz (normal duty)
660 A at 2.5 kHz (heavy duty)
maximum transient current
990 A during 60 s (heavy duty)
996 A during 60 s (normal duty)
asynchronous motor control profile
Constant torque standard
Variable torque standard
Optimized torque mode
synchronous motor control profile
Permanent magnet motor
Synchronous reluctance motor
speed drive output frequency
0.1...599 Hz
nominal switching frequency
2.5 kHz
switching frequency
2...8 kHz adjustable
2.5...8 kHz with derating factor
safety function
STO (safe torque off) SIL 3
communication port protocol
Ethernet/IP
Modbus serial
Modbus TCP
option module
Slot A : communication module for Profibus DP V1
Slot A : communication module for Profinet
Slot A : communication module for DeviceNet
Slot A : communication module for CANopen daisy chain RJ45
Slot A : communication module for CANopen SUB-D 9
Slot A : communication module for CANopen screw terminals
Slot A : communication module for EtherCAT
Slot A/slot B/slot C : digital and analog I/O extension module
Slot A/slot B/slot C : output relay extension module
Slot B : analog encoder interface module
Slot B : resolver encoder interface module
Slot B : digital encoder interface module for 5/12 V
Complementary
motor slip compensation
Adjustable
Automatic whatever the load
Can be suppressed
Not available in permanent magnet motor law
acceleration and deceleration ramps
Linear adjustable separately from 0.01...9999 s
protection type
Safe torque off motor
Motor phase break motor
Safe torque off drive
Overheating drive
Short-circuit protection drive
Motor phase break drive
Overspeed drive
Break on the control circuit drive
Overvoltages on the DC bus drive
Overload of output voltage drive
Line supply overvoltage drive
Line supply phase loss drive
Line supply undervoltage drive
Overcurrent between output phases and earth drive
Thermal protection motor
Thermal protection drive
frequency resolution
0.012/50 Hz analog input
0.1 Hz display unit
electrical connection
Removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 control
Screw terminal line side
M10 x 2 bars motor
connector type
2 RJ45 for Ethernet IP/Modbus TCP on the control block
1 RJ45 for Modbus serial on the control block
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
10/100 Mbit/s for Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
exchange mode
Half duplex, full duplex, autonegotiation for Ethernet IP/Modbus TCP
data format
8 bits, configurable odd, even or no parity for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
For Modbus serial
method of access
Slave for Modbus TCP
supply
External supply for digital inputs : 24 V DC 19...30 V <= 1.25 mA overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm) : 10.5 V DC +/- 5 % <= 10 mA overload and short-circuit protection
Internal supply for digital inputs and STO : 24 V DC 21...27 V <= 200 mA overload and short-circuit protection
local signalling
LED 3 mono/dual colour local diagnostic
LED 5 dual colour embedded communication status
LED 2 dual colour communication module status
analogue input type
Software-configurable voltage AI1, AI3 0...10 V DC 30 kOhm 12 bits
Software-configurable current AI1, AI3 0...20 mA/4...20 mA 250 Ohm 12 bits
Software-configurable voltage AI2 +/- 10 V DC 30 kOhm 12 bits
Software-configurable voltage AI2 0...10 V DC 30 kOhm 12 bits
discrete input type
Safe torque off STOA, STOB 24 V DC <= 30 V > 2.2 kOhm
Programmable DI1...DI8 24 V DC <= 30 V 3.5 kOhm
Programmable as pulse input DI7, DI8 0...30 kHz 24 V DC <= 30 V
input compatibility
Level 1 PLC EN/IEC 61131-2 STOA, STOB discrete input
Level 1 PLC EN/IEC 61131-2 DI1...DI8 discrete input
Level 1 PLC IEC 65A-68 DI7, DI8 pulse input
discrete input logic
Positive logic (source) STOA, STOB < 5 V > 11 V
Positive logic (source) DI1...DI8 < 5 V > 11 V
Negative logic (sink) DI1...DI8 > 16 V < 10 V
Positive logic (source) DI7, DI8 < 0.6 V > 2.5 V
analogue output type
Software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
discrete output type
Logic output DQ+ 0...1 kHz <= 30 V DC 100 mA
Programmable as pulse output DQ+ 0...30 kHz <= 30 V DC 20 mA
Logic output DQ- 0...1 kHz <= 30 V DC 100 mA
sampling duration
2 ms +/- 0.5 ms DI1...DI8 discrete input
5 ms +/- 1 ms DI7, DI8 pulse input
1 ms +/- 1 ms AI1, AI2, AI3 analog input
5 ms +/- 1 ms AQ1, AQ2 analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error
+/- 0.15 % of maximum value analog input AI1, AI2, AI3
+/- 0.2 % analog output AQ1, AQ2
relay output type
Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 1000000 cycles
Configurable relay logic R3 sequence relay NO 1000000 cycles
refresh time
5 ms +/- 0.5 ms R1, R2, R3 relay output
minimum switching current
5 mA 24 V DC R1, R2, R3 relay output
maximum switching current
3 A 250 V AC resistive 1 R1 relay output
3 A 30 V DC resistive 1 R1 relay output
2 A 250 V AC inductive 0.4 7 ms R1 relay output
2 A 30 V DC inductive 0.4 7 ms R1 relay output
5 A 250 V AC resistive 1 R2, R3 relay output
5 A 30 V DC resistive 1 R2, R3 relay output
2 A 250 V AC inductive 0.4 7 ms R2, R3 relay output
2 A 30 V DC inductive 0.4 7 ms R2, R3 relay output

Environment
insulation resistance
> 1 MOhm 500 V DC 1 min earth
noise level
71 dB 86/188/EEC
power dissipation in W
10250 W forced convection 2.5 kHz
THDI
<= 48 % full load conforming to IEC 61000-3-12
electromagnetic compatibility
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree
2 EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak 2...13 Hz IEC 60068-2-6
0.5 gn 13...200 Hz IEC 60068-2-6
shock resistance
7 gn 11 ms IEC 60068-2-27
relative humidity
5...95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation
40...50 °C with derating factor
-10...40 °C without
ambient air temperature for storage
-40...70 °C
operating altitude
1000...4800 m with current derating 1 % per 100 m
<= 1000 m without
environmental characteristic
Chemical pollution resistance class 3C3 EN/IEC 60721-3-3
Dust pollution resistance class 3S3 EN/IEC 60721-3-3
standards
EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
product certifications
CUL
TÜV
UL
REACH
marking
CE

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha
ATV9A0C45Q4

Schneider ATV9A0C45Q4 Variable speed drive Altivar Process Modular, ATV900, single drive, 400V, 450 kW

Schneider
2025-06-03
  • Brand: Schneider
  • Product Code: ATV9A0C45Q4
  • Availability: 10
  • $1,000.00

  • Ex Tax: $1,000.00

Tags: ATV9A0C45Q4