• Schneider TSXCTY4AC 4 channels counter modules - 40 kHz - 36 mA at 24 V DC, 330 mA at 5 V DC

Schneider TSXCTY4AC 4 channels counter modules - 40 kHz - 36 mA at 24 V DC, 330 mA at 5 V DC

Main
range of product
Modicon Premium Automation platform
product or component type
Counter modules
I/O modularity
4 channels
electrical circuit type
Auxiliary output
Complementary
counting frequency
40000 Hz
power dissipation in W
8...11.5 W
cycle time
10 ms
discrete input logic
Current sink auxiliary input (preset, enable and read) conforming to IEC 1131 Type 2
Resistive 2/3-wire proximity sensors PNP/NPN conforming to IEC 1131 Type 2
Resistive encoder input
input logic
Positive
input compatibility
Incremental encoder 10...30 V totem pole
Incremental encoder 5 V DC RS422
input voltage
24 V 18 mA 2/3-wire proximity sensors PNP/NPN
24 V 7 mA auxiliary input (preset, enable and read)
5 V 18 mA encoder input
input voltage limits
<= 5.5 V encoder input
19...30 V 2/3-wire proximity sensors PNP/NPN
19...30 V auxiliary input (preset, enable and read)
voltage state 1 guaranteed
>= 11 V 2/3-wire proximity sensors PNP/NPN
>= 11 V auxiliary input (preset, enable and read)
>= 2.4 V encoder input
current state 1 guaranteed
>= 3.7 mA encoder input
>= 6 mA 2/3-wire proximity sensors PNP/NPN
>= 6 mA auxiliary input (preset, enable and read)
voltage state 0 guaranteed
<= 1.2 V encoder input
<= 5 V 2/3-wire proximity sensors PNP/NPN
<= 5 V auxiliary input (preset, enable and read)
current state 0 guaranteed
<= 1 mA encoder input
<= 2 mA 2/3-wire proximity sensors PNP/NPN
<= 2 mA auxiliary input (preset, enable and read)
response time
< 2.5 ms sensor voltage at loss of 24 V auxiliary input (preset, enable and read)
input impedance
> 270 Ohm at U = 2.4 V encoder input
1400 Ohm at Un 2/3-wire proximity sensors PNP/NPN
3400 Ohm at Un auxiliary input (preset, enable and read)
400 Ohm at Un encoder input
output voltage
24 V DC
nominal output current
0.5 A
output voltage limits
19...30 V
voltage drop
< 0.5 V at state 1
output compatibility
Positive logic DC inputs (resistance <= 15 kOhm) auxiliary output
leakage current
< 0.1 mA
switching time
< 0.25 ms
switching frequency
< 0.6/LI² Hz on inductive load
output overload protection
Current limiter
Thermal tripping via program or automatically
output short-circuit protection
Current limiter
Thermal tripping via program or automatically
output overvoltage protection
Zener diode
reverse polarity protection
Reverse diode on supply
checks
Sensor power supply
current consumption
330 mA 5 V DC
36 mA 24 V DC
module format
Standard
local signalling
4 LEDs green axis diagnostics available (CH.)
1 LED green module operating (RUN)
1 LED red external fault (I/O)
1 LED red internal fault, module failure (ERR)
electrical connection
2 connectors HE-10 20 pins
4 connectors SUB-D 15
product weight
0.43 kg

Environment
protective treatment
Conformal coating Humiseal 1A33
TC
ambient air temperature for operation
0...60 °C
ambient air temperature for storage
-25...70 °C
relative humidity
5...95 % without condensation
operating altitude
<= 2000 m

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha
TSXCTY4AC

Schneider TSXCTY4AC 4 channels counter modules - 40 kHz - 36 mA at 24 V DC, 330 mA at 5 V DC

Schneider
2025-05-24
  • Brand: Schneider
  • Product Code: TSXCTY4AC
  • Availability: 10
  • $1,000.00

  • Ex Tax: $1,000.00

Tags: TSXCTY4AC