Schneider TM221C40R Controller M221 40 IO relay
range of product |
Modicon M221
|
|
---|---|---|
product or component type |
Logic controller
|
|
[Us] rated supply voltage |
100...240 V AC
|
|
discrete input number |
24 discrete input conforming to IEC 61131-2 Type 1
|
|
analogue input number |
2 at input range: 0...10 V
|
|
discrete output type |
Relay normally open
|
|
discrete output number |
16 relay
|
|
discrete output voltage |
5...125 V DC
5...250 V AC |
|
discrete output current |
2 A
|
discrete I/O number |
40
|
|
---|---|---|
number of I/O expansion module |
<= 7 for relay output
|
|
supply voltage limits |
85...264 V
|
|
network frequency |
50/60 Hz
|
|
inrush current |
<= 40 A
|
|
power consumption in VA |
<= 67 VA at 100...240 V with max number of I/O expansion module
<= 37 VA at 100...240 V without I/O expansion module |
|
power supply output current |
0.52 A at 5 V for expansion bus
0.24 A at 24 V for expansion bus |
|
discrete input logic |
Sink or source (positive/negative)
|
|
discrete input voltage |
24 V
|
|
discrete input voltage type |
DC
|
|
analogue input resolution |
10 bits
|
|
LSB value |
10 mV
|
|
conversion time |
1 ms per channel + 1 controller cycle time for analog input
|
|
permitted overload on inputs |
+/- 30 V DC for analog input with 5 min maximum
+/- 13 V DC for analog input permanent |
|
voltage state 1 guaranteed |
>= 15 V for input
|
|
voltage state 0 guaranteed |
<= 5 V for input
|
|
discrete input current |
7 mA for discrete input
5 mA for fast input |
|
input impedance |
4.9 kOhm for fast input
3.4 kOhm for discrete input 100 kOhm for analog input |
|
response time |
10 ms turn-on operation for output
35 µs turn-off operation for input; I2...I5 terminal 10 ms turn-off operation for output 5 µs turn-on operation for fast input; I0, I1, I6, I7 terminal 35 µs turn-on operation for input; other terminals terminal 5 µs turn-off operation for fast input; I0, I1, I6, I7 terminal 100 µs turn-off operation for input; other terminals terminal |
|
configurable filtering time |
0 ms for input
12 ms for input 3 ms for input |
|
output voltage limits |
125 V DC
277 V AC |
|
current per output common |
7 A
|
|
absolute accuracy error |
+/- 1 % of full scale for analog input
|
|
electrical durability |
Inductive AC-15, (cos phi = 0.35) 240 V / 120 VA : 100000 cycles
Resistive DC-12, 24 V / 48 W : 100000 cycles Resistive AC-12, 120 V / 240 VA : 100000 cycles Inductive AC-15, (cos phi = 0.35) 240 V / 36 VA : 300000 cycles Resistive AC-12, 120 V / 80 VA : 300000 cycles Inductive (L/R = 7 ms) DC-13, 24 V / 24 W : 100000 cycles Resistive DC-12, 24 V / 16 W : 300000 cycles Inductive (L/R = 7 ms) DC-13, 24 V / 7.2 W : 300000 cycles Inductive AC-14, (cos phi = 0.7) 240 V / 240 VA : 100000 cycles Inductive AC-15, (cos phi = 0.35) 120 V / 60 VA : 100000 cycles Inductive AC-14, (cos phi = 0.7) 240 V / 72 VA : 300000 cycles Inductive AC-15, (cos phi = 0.35) 120 V / 18 VA : 300000 cycles Resistive AC-12, 240 V / 480 VA : 100000 cycles Inductive AC-14, (cos phi = 0.7) 120 V / 120 VA : 100000 cycles Resistive AC-12, 240 V / 160 VA : 300000 cycles Inductive AC-14, (cos phi = 0.7) 120 V / 36 VA : 300000 cycles |
|
switching frequency |
20 switching operations/minute with maximum load
|
|
mechanical durability |
>= 20000000 cycles for relay output
|
|
minimum load |
1 mA at 5 V DC for relay output
|
|
protection type |
Without protection at 5 A
|
|
reset time |
1 s
|
|
memory capacity |
256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM |
|
data backed up |
256 kB built-in flash memory for backup of application and data
|
|
data storage equipment |
2 GB SD card optional
|
|
battery type |
BR2032 lithium non-rechargeable, battery life: 4 yr
|
|
backup time |
1 year at 25 °C by interruption of power supply
|
|
execution time for 1 KInstruction |
0.3 ms for event and periodic task
|
|
execution time per instruction |
0.2 µs Boolean
|
|
exct time for event task |
60 µs response time
|
|
maximum size of object areas |
8000 %MW memory words
255 %C counters 512 %M memory bits 512 %KW constant words 255 %TM timers |
|
realtime clock |
With
|
|
clock drift |
<= 30 s/month at 25 °C
|
|
regulation loop |
Adjustable PID regulator up to 14 simultaneous loops
|
|
counting input number |
4 fast input (HSC mode) (counting frequency: 100 kHz), counting
capacity: 32 bits
|
|
counter function |
Pulse/direction
Single phase A/B |
|
integrated connection type |
USB port with connector mini B USB 2.0
Non isolated serial link "serial 1" with connector RJ45 and interface RS485 Non isolated serial link "serial 2" with connector RJ45 and interface RS232/RS485 |
|
supply |
Serial serial link supply at 5 V 200 mA
|
|
transmission rate |
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of
15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232 480 Mbit/s - communication protocol: USB |
|
communication port protocol |
USB port : USB protocol - SoMachine-Network
Non isolated serial link : Modbus protocol master/slave - RTU/ASCII or SoMachine-Network |
|
local signalling |
1 LED green for SD card access (SD)
1 LED red for BAT 1 LED green for SL1 1 LED green for SL2 1 LED per channel green for I/O state 1 LED red for module error (ERR) 1 LED green for PWR 1 LED green for RUN |
|
electrical connection |
Mini B USB 2.0 connector for a programming terminal
Terminal block, 3 terminal(s) for connecting the 24 V DC power supply Connector, 4 terminal(s) for analogue inputs Removable screw terminal block for inputs Removable screw terminal block for outputs |
|
cable distance between devices |
Shielded cable: 10 m for fast input
Unshielded cable: 30 m for output Unshielded cable: 30 m for digital input Unshielded cable: 1 m for analog input |
|
insulation |
2300 V AC between output and internal logic
Non-insulated between analogue inputs 500 V AC between input and internal logic Non-insulated between analogue input and internal logic 1500 V AC between supply and ground 500 V AC between sensor power supply and ground 500 V AC between input and ground 1500 V AC between output and ground 2300 V AC between supply and internal logic 500 V AC between sensor power supply and internal logic 500 V AC between Ethernet terminal and internal logic 2300 V AC between supply and sensor power supply |
|
marking |
CE
|
|
sensor power supply |
24 V DC at 250 mA supplied by the controller
|
|
mounting support |
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit |
|
height |
90 mm
|
|
depth |
70 mm
|
|
width |
160 mm
|
|
product weight |
0.456 kg
|
standards |
EN/IEC 61010-2-201
EN/IEC 61131-2 EN/IEC 60664-1 |
|
---|---|---|
product certifications |
cULus
ABS EAC IACS E10 DNV-GL LR RCM CSA |
|
environmental characteristic |
Ordinary and hazardous location
|
|
resistance to electrostatic discharge |
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m ( 80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m ( 1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 1 V/m ( 2...2.7 GHz) conforming to EN/IEC 61000-4-3 |
|
resistance to magnetic fields |
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
|
|
resistance to fast transients |
2 kV for power lines conforming to EN/IEC 61000-4-4
2 kV for relay output conforming to EN/IEC 61000-4-4 1 kV for Ethernet line conforming to EN/IEC 61000-4-4 1 kV for serial link conforming to EN/IEC 61000-4-4 1 kV for I/O conforming to EN/IEC 61000-4-4 |
|
surge withstand |
2 kV for power lines (AC) in common mode conforming to EN/IEC
61000-4-5
2 kV for relay output in common mode conforming to EN/IEC 61000-4-5 1 kV for I/O in common mode conforming to EN/IEC 61000-4-5 1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5 1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5 0.5 kV for power lines (DC) in common mode conforming to EN/IEC 61000-4-5 |
|
resistance to conducted disturbances |
10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 Vrms (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 Vrms (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) |
|
electromagnetic emission |
Conducted emissions conforming to EN/IEC 55011 power lines (AC),
0.15...0.5 MHz : 79 dBμV/m QP/66 dBμV/m AV
Conducted emissions conforming to EN/IEC 55011 power lines (AC), 0.5...300 MHz : 73 dBμV/m QP/60 dBμV/m AV Conducted emissions conforming to EN/IEC 55011 power lines, 10...150 kHz : 120...69 dBµV/m QP Conducted emissions conforming to EN/IEC 55011 power lines, 1.5...30 MHz : 63 dBμV/m QP Radiated emissions conforming to EN/IEC 55011 class A 10 m, 30...230 MHz : 40 dBμV/m QP Conducted emissions conforming to EN/IEC 55011 power lines, 150...1500 kHz : 79...63 dBμV/m QP Radiated emissions conforming to EN/IEC 55011 class A 10 m, 200...1000 MHz : 47 dBμV/m QP |
|
immunity to microbreaks |
10 ms
|
|
ambient air temperature for operation |
-10...55 °C for horizontal installation
-10...35 °C for vertical installation |
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
10...95 % without condensation in operation
10...95 % without condensation in storage |
|
IP degree of protection |
IP20 with protective cover in place
|
|
pollution degree |
<= 2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0...3000 m
|
|
vibration resistance |
3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
1 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail 3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting 1 gn (vibration frequency: 8.4...150 Hz) on panel mounting |
|
shock resistance |
98 m/s² (test wave duration:11 ms)
|
Schneider TM221C40R Controller M221 40 IO relay
- Brand: Schneider
- Product Code: TM221C40R
- Availability: 10
-
$1,000.00
- Ex Tax: $1,000.00
Tags: TM221C40R