• Schneider TM241CEC24R Controller M241 24 IO relay Ethernet CAN master

Schneider TM241CEC24R Controller M241 24 IO relay Ethernet CAN master

Main
range of product
Modicon M241
product or component type
Logic controller
[Us] rated supply voltage
100...240 V AC
discrete input number
14 discrete input including 8 fast input conforming to IEC 61131-2 Type 1
discrete output type
Transistor
Relay
discrete output number
6 relay
4 transistor including 4 fast output
discrete output voltage
24 V DC for transistor output
5...125 V DC for relay output
5...250 V AC for relay output
discrete output current
2 A with Q4...Q9 terminal(s) for relay output
0.1 A with TR0...TR3 terminal(s) for fast output (PTO mode)
0.5 A with TR0...TR3 terminal(s) for transistor output
Complementary
discrete I/O number
24
number of I/O expansion module
7 (local I/O architecture)
14 (remote I/O architecture)
supply voltage limits
85...264 V
network frequency
50/60 Hz
discrete input logic
Sink or source
discrete input voltage
24 V
discrete input voltage type
DC
voltage state 1 guaranteed
>= 15 V for input
voltage state 0 guaranteed
<= 5 V for input
discrete input current
5 mA for input
input impedance
4.7 kOhm for input
response time
50 µs turn-on operation with I0...I13 terminal(s) for input
configurable filtering time
1 µs for fast input
discrete output logic
Positive logic (source)
output voltage limits
125 V DC relay output
30 V DC transistor output
277 V AC relay output
output frequency
<= 1 kHz for transistor output
<= 20 kHz for fast output (PWM mode)
<= 100 kHz for fast output (PLS mode)
accuracy
+/- 0.1 % at 0.02...0.1 kHz for fast output
+/- 1 % at 0.1...1 kHz for fast output
protection type
Short-circuit protection for transistor output
Short-circuit and overload protection with automatic reset for transistor output
Reverse polarity protection for transistor output
Without protection for relay output
reset time
10 ms automatic reset output
12 s automatic reset fast output
memory capacity
8 MB for program
64 MB for system memory RAM
data backed up
128 MB built-in flash memory for backup of user programs
data storage equipment
<= 16 GB SD card optional
battery type
BR2032 lithium non-rechargeable, battery life: 4 yr
backup time
2 years at 25 °C
execution time for 1 KInstruction
0.3 ms for event and periodic task
0.7 ms for other instruction
application structure
3 cyclic master tasks + 1 freewheeling task
4 cyclic master tasks
8 external event tasks
8 event tasks
realtime clock
With
clock drift
<= 60 s/month at 25 °C
positioning functions
PTO function 4 channel(s) (positioning frequency: 100 kHz)
counting input number
4 fast input (HSC mode) at 200 kHz
14 standard input at 1 kHz
control signal type
A/B signal at 100 kHz for fast input (HSC mode)
Pulse/direction signal at 200 kHz for fast input (HSC mode)
Single phase signal at 200 kHz for fast input (HSC mode)
integrated connection type
USB port with connector mini B USB 2.0
Ethernet with connector RJ45
Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485
Non isolated serial link "serial 2" with connector removable screw terminal block and interface RS485
CANopen J1939 with connector male SUB-D 9
supply
Serial link supply "serial 1" at 5 V, <= 200 mA
transmission rate
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m - communication protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication protocol: RS232
480 Mbit/s for bus length of 3 m - communication protocol: USB
10/100 Mbit/s - communication protocol: Ethernet
1000 kbit/s for bus length of 20 m - communication protocol: CANopen
800 kbit/s for bus length of 40 m - communication protocol: CANopen
500 kbit/s for bus length of 100 m - communication protocol: CANopen
250 kbit/s for bus length of 250 m - communication protocol: CANopen
125 kbit/s for bus length of 500 m - communication protocol: CANopen
50 kbit/s for bus length of 1000 m - communication protocol: CANopen
20 kbit/s for bus length of 2500 m - communication protocol: CANopen
communication port protocol
Modbus non isolated serial link with master/slave method
port Ethernet
1 - 10BASE-T/100BASE-TX port with copper cable support
ethernet services
Ethernet/IP adapter
DHCP client
IEC VAR ACCESS
Modbus TCP client
Modbus TCP server
Modbus TCP slave device
SNMP client/server
FTP client/server
SQL client
Send and receive email from the controller based on TCP/UDP library
Web server (WebVisu & XWeb system)
OPC UA server
DNS client
local signalling
1 LED green for SD card access (SD)
1 LED red for BAT
1 LED green for SL1
1 LED green for SL2
1 LED per channel green for I/O state
1 LED red for I/O error (I/O)
1 LED red for bus fault on TM4 (TM4)
1 LED green for Ethernet port activity
1 LED green for CANopen run
1 LED green for CANopen error
1 LED red for module error (ERR)
1 LED green for PWR
1 LED green for RUN
electrical connection
Removable screw terminal block for inputs and outputs (pitch 5.08 mm)
Removable screw terminal block for connecting the 24 V DC power supply (pitch 5.08 mm)
cable distance between devices
Unshielded cable: <= 50 m for input
Shielded cable: <= 10 m for fast input
Unshielded cable: <= 50 m for output
Shielded cable: <= 3 m for fast output
insulation
500 V AC between supply and internal logic
Non-insulated between supply and ground
marking
CE
sensor power supply
24 V DC at 400 mA supplied by the controller
surge withstand
2 kV for power lines (AC) in common mode conforming to EN/IEC 61000-4-5
2 kV for relay output in common mode conforming to EN/IEC 61000-4-5
1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5
1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5
1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5
1 kV for input in common mode conforming to EN/IEC 61000-4-5
1 kV for transistor output in common mode conforming to EN/IEC 61000-4-5
web services
Web server
maximum number of connections
16 connection(s) for Ethernet/IP device
8 connection(s) for Modbus server
CANopen feature profile
DR 303-1
DS 301 V4.02
number of slave
63 CANopen
mounting support
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Plate or panel with fixing kit
height
90 mm
depth
95 mm
width
150 mm
product weight
0.53 kg

Environment
standards
CSA C22.2 No 142
ANSI/ISA 12-12-01
UL 1604
CSA C22.2 No 213
EN/IEC 61131-2 : 2007
Marine specification (LR, ABS, DNV, GL)
UL 508
product certifications
CSA
IACS E10
RCM
cULus
resistance to electrostatic discharge
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields
10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3
resistance to fast transients
2 kV for power lines conforming to EN/IEC 61000-4-4
2 kV for relay output conforming to EN/IEC 61000-4-4
1 kV for Ethernet line conforming to EN/IEC 61000-4-4
1 kV for serial link conforming to EN/IEC 61000-4-4
1 kV for input conforming to EN/IEC 61000-4-4
1 kV for transistor output conforming to EN/IEC 61000-4-4
resistance to conducted disturbances
10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emission
Conducted emissions, test level: 120...69 dBµV/m QP, condition of test: power lines (radio frequency: 10...150 kHz) conforming to EN/IEC 55011
Conducted emissions, test level: 63 dBμV/m QP, condition of test: power lines (radio frequency: 1.5...30 MHz) conforming to EN/IEC 55011
Conducted emissions, test level: 79 dBμV/m QP/66 dBμV/m AV, condition of test: power lines (radio frequency: 0.15...0.5 MHz) conforming to EN/IEC 55011
Conducted emissions, test level: 73 dBμV/m QP/60 dBμV/m AV, condition of test: power lines (radio frequency: 0.5...300 MHz) conforming to EN/IEC 55011
Radiated emissions, test level: 40 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 30...230 MHz) conforming to EN/IEC 55011
Conducted emissions, test level: 79...63 dBμV/m QP, condition of test: power lines (radio frequency: 150...1500 kHz) conforming to EN/IEC 55011
Radiated emissions, test level: 47 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 230...1000 MHz) conforming to EN/IEC 55011
immunity to microbreaks
10 ms
ambient air temperature for operation
-10...55 °C for horizontal installation
-10...50 °C for vertical installation
ambient air temperature for storage
-25...70 °C
relative humidity
10...95 % without condensation in operation
10...95 % without condensation in storage
IP degree of protection
IP20 with protective cover in place
pollution degree
2
operating altitude
0...2000 m
storage altitude
0...3000 m
vibration resistance
3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
3 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail
3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting
3 gn (vibration frequency: 8.4...150 Hz) on panel mounting
shock resistance
15 gn for 11 ms

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha
TM241CEC24R

Schneider TM241CEC24R Controller M241 24 IO relay Ethernet CAN master

Schneider
2025-05-23
  • Brand: Schneider
  • Product Code: TM241CEC24R
  • Availability: 10
  • $1,000.00

  • Ex Tax: $1,000.00

Tags: TM241CEC24R