• Schneider TM4PDPS1 Module network TM4 1 Profibus DP slave

Schneider TM4PDPS1 Module network TM4 1 Profibus DP slave

Main
product or component type
Profibus DP communication module
Complementary
range compatibility
Modicon M241
Modicon M251
product compatibility
Modicon M241 logic controller
Modicon M251 logic controller
current consumption
290 mA at 5 V DC for communication bus
power dissipation in W
1.5 W
integrated connection type
Female SUB-D 9 Profibus DP
transmission rate
1.5 Mbit/s for bus length of 200 m
500 kbit/s for bus length of 400 m
187.5 kbit/s for bus length of 1000 m
9.6...93.75 kbit/s for bus length of 1200 m
3...12 Mbit/s for bus length of 100 m
communication port protocol
Profibus DP V1
Profibus DP V0
insulation
Between bus and internal logic at 1000 V DC
local signalling
1 LED green/yellow for power supply
1 LED green/red for communication
electrical connection
Screw connector - terminal for connecting the functional ground
SUB-D 9 - 1 female connector for connecting Profibus
marking
CE
surge withstand
1 kV (power lines (DC)) with common mode protection conforming to EN/IEC 61000-4-5
2 kV (power lines (AC)) with common mode protection conforming to EN/IEC 61000-4-5
2 kV (relay output) with common mode protection conforming to EN/IEC 61000-4-5
1 kV (I/O) with common mode protection conforming to EN/IEC 61000-4-5
1 kV (shielded cable) with common mode protection conforming to EN/IEC 61000-4-5
0.5 kV (power lines (DC)) with differential mode protection conforming to EN/IEC 61000-4-5
1 kV (power lines (AC)) with differential mode protection conforming to EN/IEC 61000-4-5
1 kV (relay output) with differential mode protection conforming to EN/IEC 61000-4-5
0.5 kV (I/O) with differential mode protection conforming to EN/IEC 61000-4-5
mounting support
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Plate or panel with fixing kit
width
25 mm
height
90 mm
depth
90 mm
product weight
0.1 kg

Environment
standards
UL 508
EN/IEC 61131-2
EIA-485
product certifications
C-Tick
cULus
resistance to electrostatic discharge
8 kV (in air) conforming to Marine specification (LR, ABS, DNV, GL)
6 kV (on contact) conforming to Marine specification (LR, ABS, DNV, GL)
4 kV (on contact) conforming to EN/IEC 61000-4-2
8 kV (in air) conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields
10 V/m (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
1 V/m (2...2.7 GHz) conforming to EN/IEC 61000-4-3
resistance to fast transients
2 kV (relay output) conforming to EN/IEC 61000-4-4
1.5 kV (I/O) conforming to EN/IEC 61000-4-4
1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
1 kV (serial link) conforming to EN/IEC 61000-4-4
2 kV (power lines) conforming to EN/IEC 61000-4-4
resistance to conducted disturbances
10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emission
Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10...150 kHz conforming to EN/IEC 55011
Conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15...0.5 MHz conforming to EN/IEC 55011
Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5...300 MHz conforming to EN/IEC 55011
Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5...30 MHz conforming to EN/IEC 55011
Radiated emissions - test level: 40 dBμV/m QP class A at 30...230 MHz conforming to EN/IEC 55011
Radiated emissions - test level: 60...54 dBμV/m QP at 30...100 MHz conforming to Marine specification (LR, ABS, DNV, GL)
Radiated emissions - test level: 24 dBμV/m QP at 156...165 MHz conforming to Marine specification (LR, ABS, DNV, GL)
Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150...1500 kHz conforming to EN/IEC 55011
Radiated emissions - test level: 47 dBμV/m QP class A at 230...1000 MHz conforming to EN/IEC 55011
Radiated emissions - test level: 80...50 dμV/m QP at 150...30000 kHz conforming to Marine specification (LR, ABS, DNV, GL)
Radiated emissions - test level: 54 dBμV/m QP at 100...2000 MHz conforming to Marine specification (LR, ABS, DNV, GL)
ambient air temperature for operation
-10...55 °C horizontal installation
-10...50 °C vertical installation
ambient air temperature for storage
-25...70 °C
relative humidity
10...95 % without condensation in operation
10...95 % without condensation in storage
IP degree of protection
IP20 with protective cover in place
pollution degree
2
operating altitude
0...2000 m
storage altitude
0...3000 m
vibration resistance
1 mm at 5...13.2 Hz on symmetrical rail
3 gn at 8.7...150 Hz on symmetrical rail
1 mm at 5...13.2 Hz on panel mounting
0.7 gn at 13.2...100 Hz on panel mounting
shock resistance
15 gn during 11 ms